Replace the two-attempt read with a single read sized to the smaller of:
- detourLength + 16 (the decoder's preferred window), and
- bytes remaining in the current page (so ReadProcessMemory does not fail whole read).
Reading only detourLength bytes could leave the instruction analyzer without enough
bytes to resolve a multi-byte instruction that crosses the splice point on
sparse prologues. Reading up to the page boundary gives the largest safe window.
Tests: 199 passing, 4 integration/interactive skipped.